Video Tutorials →Mastering Insulation Resistance Testing Theory + Practical
Published by: LeeAndro on 3-12-2020, 05:28 | 0

MP4 | Video: h264, 1280x720 | Audio: AAC, 44.1 KHz, 2 Ch
Genre: eLearning | Language: English + .srt | Duration: 61 lectures (3h 20m) | Size: 2.52 GB
Cable, Transformer, Generator, Motor, Bushing, Circuit Breaker Insulation Resistance Testing.
A Must Course for All Engg
Concept of Insulation Resistance
Leakage Current & Its Component
Insulation Resistance Test
d Insulation Resistance test
Di-Electric Absorption Ratio Test , Reading at 30 Sec & 1 Min
Polarization Index Test
Die-Electric Discharge Test
Variable Voltage Range
Ramp Test
What Causes Insulation Resistance to Degrade
How Insulation Resistance Test Set work
Understanding Insulation resistance distribution
Understanding Leakage Current
Direction of Leakage Current
Principle of measurement for Insulation Resistance
Equivalent Circuit of Insulation Resistance
Formula to calculate insulation Resistance
Understanding types of leakage current Conductive Leakage Current Capacitive Leakage Current Polarization / Absorption Leakage Current Surface Leakage Current
Understanding Chag Current
Capacitance Distribution
Capacitance Equivalent circuit of three phase circuit
How Cable Chag works Chag Constant Calculating 5T Effect of Chag Current on reading of IR Polarization / Absorption Current Die Electric absorption in detail Understanding Current Curves ( Conduction, Capacitive, Polarization)
Selection of Applied Voltage as per IEEE standard 43 Application of IR Test How to make connections & different combinations to test Understanding Test Connection Proof Testing / Installation Testing Maintenance Testing Spot / Short resistance test d Resistance Test
Step Voltage test Analyzing Step Curve Di-Electric Absorption Test Analyzing Curve for Di-Electric Absorption Test Various Insulation Resistance Test
Temperature correction for testing rotating machines Analyzing curve for Temperature Co-efficient Factor Testing Wiring Mr Testing Calculation Example Connection Diagram of Cable testing Connection Diagram of Motor testing Connection Diagram of Generator testing Connection Diagram of Circuit Breaker Testing Connection Diagram of Bushing testing
Understanding Voltage Characteristics for IR Tester Analyzing Curve for IR Tester Guard Teal Guard Teal Connection Guard Teal Equivalent Circuit Example of using Guard connection for accuracy The Guard Teal as Diagnostic Tool
Basic Understanding
Content of Course
Definition of Insulation Resistance
What Causes Insulation Resistance to Degrade
How Insulation Resistance Test Set work
Understanding Insulation resistance distribution
Understanding Leakage Current
Direction of Leakage Current
Principle of measurement for Insulation Resistance
Equivalent Circuit of Insulation Resistance
Formula to calculate insulation Resistance
Understanding types of leakage current
Conductive Leakage Current
Capacitive Leakage Current
Polarization / Absorption Leakage Current
Surface Leakage Current
Understanding Chag Current
Capacitance Distribution
Capacitance Equivalent circuit of three phase circuit
How Cable Chag works
Chag Constant
Calculating 5T
Effect of Chag Current on reading of IR
Polarization / Absorption Current
Die Electric absorption in detail
Understanding Current Curves ( Conduction, Capacitive, Polarization)
Selection of Applied Voltage as per IEEE standard 43
Application of IR Test
How to make connections & different combinations to test
Understanding Test Connection
Proof Testing / Installation Testing
Maintenance Testing
Spot / Short resistance test
d Resistance Test
Step Voltage test
Analyzing Step Curve
Di-Electric Absorption Test
Analyzing Curve for Di-Electric Absorption Test
Various Insulation Resistance Test
Temperature correction for testing rotating machines
Analyzing curve for Temperature Co-efficient Factor
Testing Wiring
Mr Testing Calculation Example
Connection Diagram of Cable testing
Connection Diagram of Motor testing
Connection Diagram of Generator testing
Connection Diagram of Circuit Breaker Testing
Connection Diagram of Bushing testing
Understanding Voltage Characteristics for IR Tester
Analyzing Curve for IR Tester
Guard Teal
Guard Teal Connection
Guard Teal Equivalent Circuit
Example of using Guard connection for accuracy
The Guard Teal as Diagnostic Tool
Introduction to ANSI/IEEE Std 95-1977
Demonstration of Mr Video
Video How to Test Cable
Video How to Test Transformer
Video How to Test Motor
insulation resistance
An insulation resistance (IR) test measures the total resistance between any two points separated by electrical insulation. The test, therefore, detees how effective the dielectric (insulation) is in resisting the flow of electrical current
Insulation Resistance / Mr Test
Most commonly referred to as simply a "mr," the insulation resistance test set (or Megohmeter) is used to detee the condition of insulation on various types of electrical equipment like cables, transformers and switchgear.
Tests are typically conducted by applying a direct current (dc) voltage to the conductor under test and measuring the current that flows through insulation (called the "leakage current") and into the non-current carrying metal parts of equipment. Contaminated insulation can be deteed by observing the absorption current - or current absorbed by the insulation - over a specified period of .
What Causes insulation to Degrade?
Electrical Stress
Mechanical Stress
Chal Attack
Thermal Stress
Environmental Contamination
How an Insulation Resistance Tester Operates
The Mr insulation tester is essentially a high-range resistance meter (ohmmeter) with a built-in dc generator.
The instrument's generator, which can be hand-cranked, battery or line-operated, develops a high dc voltage that causes several small currents through and over surfaces of the insulation being tested.
The total current is measured by the ohmmeter, which has an analog indicating scale, digital readout or both
Insulation Resistance / Mr Test Record keeping
Insulation-resistance test data may be used to establish a trending pattern with deviations from the baseline information pe evaluation of insulation. The results of these tests (typically expressed in Megohms) are dependent on the temperature of the insulating material and the humidity of the surrounding environment at the of testing; therefore all readings must be corrected to a base temperature, such as 20°C.
How much voltage can a be produced?
Insulation testers come in a variety of sizes and output voltages depending on its specific application. A handheld 1000V Megohmeter is usually sufficient for 600V class equipment while larger sets for use on high voltage apparatus can output up to 15,000V or more.
Mr Test Connections
There are three test teals on an insulation resistance tester marked positive (+), negative (-) and Guard (G). Most basic measurements utilize only the positive and negative teals, such as in cases when there is little possibility of adverse current paths that could affect the result.
When testing at higher voltages, such as with cable or transformers, the guard teal can be used to divert surface leakage from the measuring circuit. Not all insulation testers are equipped with a guard teal.
Note: Handheld megohmeters with outputs of 1000V or less may not be equipped with a Guard teal.
What is Insulation Resistance
No insulation is ideal and hence there will be always some leakage current from insulation to ground, when voltage is applied.
Leakage Current Direction
How to Measure Insulation Resistance
Insulation Resistance is measured by Ohm's Law
Insulation Resistance = Applied Voltage / Leakage Current
Applied Voltage = 1000 V
Measure Leakage Current = 0.001Amp
Measured Insurance Resistance = 10 Mega Ohms
Understanding Insulation Resistance Equivalent Circuit
finding Insulation Resistance value by using formula
Leakage Current Types
There are two types of leakage current
1.Conductive Leakage Current
2.Capacitive Chag leakage Current
3.Polarizing / Absorption Current
4.Surface Leakage Current
Different types of leakage Currents & its effect on readings
The total current is the sum of these components. (Leakage current is shown as one current.) It is this current that can be measured directly by a microammeter or, in terms of megohms, at a particular voltage by means of a Mr insulation tester. Some instruments offer the alternatives of displaying a measurement in terms of current or as a resistance.
Because the total current depends upon the that the voltage is applied, Ohm's Law (R = E/I) only holds, theoretically, at an infinite (that implies waiting forever before taking a reading). It is also highly dependent upon starting from a base level of total discharge. The first step in any insulation test is, therefore, to ensure that the insulation is completely discharged
Conduction current
Conduction current is steady through the insulation and is usually represented by a very high value resistor in parallel with the capacitance of the insulation. It is a component of the Leakage Current, which is the current that would be measured when the insulation is fully charged and full absorption has taken place. Note that it includes surface leakage, which can be reduced or eliminated by the use of the guard teal (to be discussed later).
The graph in Figure 2 shows the nature of each of the components of current with respect to .
Surface Leakage Current
The surface leakage current is present because the surface of the insulation is contaminated with moisture or salts. The current is constant with and depends on the degree of ionization present, which is itself dependent on temperature. It is often ignored as a separate current, being included with the conduction current below as the total leakage current.
Capacitive chag leakage current (IC )
When two or more conductors are run together in a raceway, they act as a capacitor. Due to this capacitive effect, a leakage current flows through conductor insulation. This current lasts only for a few seconds as the dc voltage is applied and drops out after the insulation has been charged to its full test voltage. In low-capacitance equipment, the capacitive current is higher than conductive leakage current, but usually disappears by the we start recording the data. Because of this, it is important to let the reading "settle out" before recording it. On the other hand, when testing high capacitance equipment the capacitive chag leakage current can last for a very long before settling out.
Polarization / absorption leakage current (IA )
Absorption current is caused by the polarization of molecules within dielectric material.
The positive and negative charges in molecules separate, causing an increase in the state of polarization P. A chag state of polarization corresponds to charge movement and so is equivalent to a current, hence the term "polarization current".
Absorption current is actually made up of up to three components, which decay at a decreasing rate to a value close to zero over a period of several minutes. The first is caused by a general drift of free electrons through the insulation under the effect of the electric field.
Components of test currents
Capacitor Chag Behavior
Capacitance of cable is distributed along cable.
Capacitance is added in parallel hence it will be added
Longer is the cable more will be the capacitance
Capacitance Equivalent circuit of three phase circuit
Capacitor Chag
Chag
Chag Current will decay when Capacitor is charged
After cable / equipment is charged Capacitive chag current reduces to zero.
Constant = T = RC
Capacitor Charge in 5T
Effect of Chag Current on Reading of Insulation Resistance
Insulation Resistance can be defined as
IR = V applied / I conductive resistive leakage current
But in practical there is Capacitive Leakage current is also available due to capacitance of cable.
Tester Read IR = V / ( I R + I C )
I C decays to Zero after 5T and reading become stable.
Initially Tester will show low reading and with it will increase & become stable
Testing of IR
During the testing procedure, the high dc voltage generated by pressing the test button will cause a small (micro-amps) current flow through the conductor and the insulation. The amount of current depends on the amount of voltage applied, the system's capacitance, the total resistance, and the temperature of the material. For a fixed voltage, the higher the current, the lower the resistance (E=IR, R=E/I). The total resistance is the sum of the internal resistance of the conductor (small value) plus the insulation resistance in MΩs
Dielectric polarization
Dielectric polarization is the term given to describe the behavior of a material when an external electric field is applied on it. A simple picture can be made using a capacitor as an example. ... The charges in the material will have a response to the electric field caused by the plates
Absorption current
Absorption current is actually made up of up to three components, which decay at a decreasing rate to a value close to zero over a period of several minutes.
The first is caused by a general drift of free electrons through the insulation under the effect of the electric field. A Guide to Diagnostic Insulation Testing Above 1 kv 7
The second is caused by molecular distortion whereby the imposed electric field distorts the negative charge of the electron shells circulating around the nucleus toward the positive voltage.
The third is due to the alignment of polarized molecules within the electric field applied. This alignment is fairly random in a neutral state, but when an electric field is applied, these polarized molecules line up with the field to a greater or lesser extent.
Polarization
How Much Voltages should be applied for different insulations
Application of IR Test
Installation Test
The most important reason for testing insulation is to insure public and personal safety
By perfog a high dc voltage test between de-energized current-carrying (hot), grounded, and grounding conductors, you can eliminate the possibility of having a life-threatening short circuit or short to ground.
Maintenance Test
The second most important rea- son for insulation testing is to protect and prolong the life of electrical systems and motors.
Over the years, electrical systems are exposed to environmental factors such as dirt, grease, temperature, stress, and vibration. These conditions can lead to insulation failure, resulting in loss of production or even fires. Periodic maintenance tests can provide valuable information about the state of deterioration and will help in predicting possible failure of the system.
Installation Test / Proof Testing
To Check Healthiness of installed equipment / Cables
The proof test is a simple, quick test used to indicate the instantaneous condition of insulation.
It provides no diagnostic data and the test voltages used are much higher than the voltages used in predictive maintenance tests. The proof test is somes called GO/NO GO TEST because it tests cable systems for maintenance errors, incorrect installation, serious degradation, or contamination.
The installation is declared acceptable if no breakdown occurs during testing.
Choosing the test voltage
Choosing the test voltage
Proof test procedure
Proof Testing
Predictive maintenance tests
Spot-reading/short- resistance test
Selection of Voltage level
Formula to apply voltages
Insulation Resistance test curve
IR over period of
Step Voltage Curve
Step voltage test
Step Voltage Curve
Analyzing Good V/s Poor Insulator after step voltage test
Dielectric-absorption/ -resistance test
Dielectric absorption test, Dielectric Absorption Ratios, Various Insulation test Chart, Dielectric Discharge Test, Polarization Index , D.A. and PI Comparison, Temperature correction for testing rotating machines, How to make connections & different combinations, Testing generators and motors, Testing transformers, Testing wiring and cable installations, Calculation Example, Pre-Testing Requirement How to setup connections, Work safely, Connection Diagram for Motor, Transformer, Cable, Generator, Voltage Characteristics, The Guard Teal, Introduction to ANSI/IEEE Std IEEE Std P43-2000, Demonstration of Mr Test
Student, Eeer, Professionals
DOWNLOAD
uploadgig
https://uploadgig.com/file/download/50D52afab35e5744/i0zADloG__Mastering_.part1.rar
https://uploadgig.com/file/download/51c2B800797a9683/i0zADloG__Mastering_.part2.rar
https://uploadgig.com/file/download/4faE3f7f60114d1e/i0zADloG__Mastering_.part3.rar
rapidgator
https://rapidgator.net/file/41b2c4d4f3331767a66e4f867d15a7b9/i0zADloG__Mastering_.part1.rar.html
https://rapidgator.net/file/1a341303f31485497f38ac173635d1f3/i0zADloG__Mastering_.part2.rar.html
https://rapidgator.net/file/2c3b940de0b614282d9377f8f7437b20/i0zADloG__Mastering_.part3.rar.html
nitroflare
Related News
- Insulation Resistance (IR) test course for Power cables
- High Voltage and Insulators for Electrical Power Engineering
- Electrical, Electronics and PCB Design Safety & Compliance
- High Voltage and Insulators for Electrical Power Engineering
- Physics - Electricity - High School and AP Physics Ohm's Law, Voltage, Current, and Resistance
Comments (0)
Search
Calendar
« January 2021 » | ||||||
---|---|---|---|---|---|---|
Mon | Tue | Wed | Thu | Fri | Sat | Sun |
1 | 2 | 3 | ||||
4 | 5 | 6 | 7 | 8 | 9 | 10 |
11 | 12 | 13 | 14 | 15 | 16 | 17 |
18 | 19 | 20 | 21 | 22 | 23 | 24 |
25 | 26 | 27 | 28 | 29 | 30 | 31 |